banner
Home>>News>>FAQs

How to maintain the plane mask machine?

  • Edit:Guangdong KYD precision machinery co., ltd
  • Date:2023-11-09
  • Visits:1079
  • Sort:FAQs

The daily maintenance of the plane mask machine is very important. At ordinary times, irregular maintenance of the mask machine can make the mask machine work more efficiently, and also greatly improve the safety of workers at work. So in detail, how do we specifically maintain the mask machine?

The plane mask machine can be maintained according to the following aspects, and it is necessary to shut down the power during the maintenance process.

1. Ultrasonic system

We need to check in advance whether the system of the ultrasonic mask machine is kept clean at all times, especially the ultrasonic box, welding head and vibrator must be kept dry and clean, and the connecting wires need to be checked regularly for firmness and neatness. In addition, we need to pay attention to the change range of voltmeter and ammeter pointers on the ultrasonic box when checking the wear degree of the ultrasonic welding head.

2. Pneumatic system

The air filter cup of the mask machine needs to be checked to see if there is any water leakage, and the air compressor needs to be drained by the way. In view of the high humidity area, it is necessary to drain the air compressor every day to check whether there is any air leakage in all air pipes and cylinders, so as to ensure that the equipment can operate normally at work.

3. Appearance

Our masks are worn on the face, and medical masks need to follow the doctor into the operating room. Therefore, the production of masks requires high cleanliness of mask machines and equipment. Therefore, basically, we need to wait until after work to arrange some special cleaning personnel to clean and maintain the mask machines and equipment. Clean the countertop of the equipment and the plate containing the mask. However, it should be noted that the equipment cannot be washed directly with water, so it is necessary to clean the mask machine with some volatile cleaning liquid of alcohol.

4. Electrical system

Check whether the circuit connector of the mask machine is loose, whether the main power cord and branch signal cord are worn or aging, whether the power cord is in a dry environment, and whether the exhaust fan on the equipment can work normally.

5. Transmission system

The transmission system includes motor, gear, reducer, sprocket, chain, conveyor belt and other main components. We need to check whether the motor is attached with dust or other items that affect heat dissipation, and whether the gears and sprockets are oiled. If there are some attachments that need to be cleaned at this time, whether the tightness of the chain is appropriate, whether the connecting screws between the transmission parts are loose, and whether the lubricating oil of the reducer is enough, we usually need to replace the machinery and equipment every 1000-1500 hours.

6. Rust prevention

Corrosive liquids and objects, including sweat, should not be adhered to the flat mask machine equipment. Because sweat can easily lead to rust on the parts of the equipment. If the equipment does not work for a long time, it is necessary to apply antirust oil on the transmission system and rust-prone parts of the mask.